US-REGEN Documentation

Overview

Summary

The U.S. Regional Economy, Greenhouse Gas, and Energy Model (US-REGEN) is an energy-economy model developed and maintained by the Electric Power Research Institute (EPRI). It links a detailed electric sector capacity planning and fuels supply model with a technologically detailed consumer choice model of end-use service and energy demands. The electric-fuels model jointly optimizes regional investments in electricity generation, storage, transmission, and non-electric fuel supply with system dispatch, including high temporal resolution and chronology to characterize system interactions between variable and dispatchable resources. The electric-fuels and end-use models are solved iteratively to convergence, allowing analysis of policy impacts on the electric and fuels supply sectors taking into account electricity demand responses, and conversely allowing analysis of how economy-wide energy policies and technological improvements impact electric demand and load shapes. The electric sector module can also be run separately with higher regional and temporal resolution, or for a single year with hourly resolution and unit commitment constraints. This structure makes US-REGEN capable of modeling a wide range of environmental and energy policies in both the electric and non-electric sectors. Figure 1 illustrates the scope and inter-connections across the energy system pathways modeled in US-REGEN.

Figure 1: Energy system pathways represented in US-REGEN

US-REGEN is a regional model of the United States. It can consider multiple sub-regions of the continental U.S., to account for differences in resource endowments, energy demand, costs, policies, and policy impacts, as well as transmission of electricity. By default, the model uses 16 sub-regions, each an aggregation of states, but the model can be configured with any aggregation of the lower 48 states or in some cases sub-state areas such as electricity system zones based on the boundaries of independent system operators (ISOs) and regional transmission operators (RTOs). A separate version of the model including Canadian provinces is also available. Figure 2 shows a map of the default sub-regions in the model.[1] US-REGEN is an inter-temporal optimization model. By default it solves in five year time-steps from 2015 through 2050, but can be configured to use other time-steps and base years.

Figure 2: Default regional structure of US-REGEN model

The electric sector component of US-REGEN is a detailed generation planning model. In each time step, the model makes decisions about capacity (e.g. new investments, retrofits, and/or retirements) and dispatch to meet energy demand for both generation and inter-region transmission. It uses a bottom-up representation of power generation capacity and dispatch across a range of intra-annual time segments. It models transmission capacity between regions and requires that generation and load plus net exports and line losses balance in each time segment and for each region. The fuels component of US-REGEN represents the primary supply of fossil fuels and bioenergy, as well as conversions of these resources to non-electric end-use fuels, including hydrogen and other low-carbon fuels, which can be blended for delivery to the electric and end-use sectors. The electric-fuels model also represents the storage and delivery of fuels and includes carbon management options such as direct air capture and natural climate solutions. Fuel demands from the electric sector and end-use sectors are resolved with economy-wide market-clearing constraints, potentially including policy constraints on economy-wide emissions, providing endogenous delivered fuel prices to the end-use model.

The end-use component of US-REGEN represents trade-offs between end-use technologies and fuels for a wide range of disaggregated sectors and activities with economy-wide coverage. The model includes structural detail across several dimensions relevant for fuel and technology choice, such as building size, type, and vintage, climate zone and location, and vehicle ownership and driving intensity. Within each structural category, service demand may be met with a range of options, characterized as combinations of fuels and technologies. The model evaluates the total cost of each option in each new vintage based on assumed technology cost and performance, fuel prices, structural attributes of service demand, and non-economic factors. The resulting allocation across the options is based on a logit model translating relative costs to equilibrium market shares, with a lagged process to simulate a gradual transition toward the model's calculated equilibrium shares. The model then calculates annual and hourly fuel use by region as a function of the resulting mix of end-use technologies. The output demands of electricity and non-electric fuels from the end-use model are inputs to the electric-fuels model.

The electric-fuels model is formulated as a large-scale linear programming problem. The end-use model is a set of modules representing different sectors, which are formulated using a mix of logit simulation and linear programming methods. Each model component is implemented within the GAMS software environment.

US-REGEN uses several primary sources to calibrate to observed data:

  • Energy data from the U.S. Energy Information Administration (EIA), including:
    • Annual Electric Power Industry Report (Form 861)
    • Residential Energy Consumption Survey (RECS)
    • Commercial Buildings Energy Consumption Survey (CBECS)
    • Manufacturing Energy Consumption Survey (MECS)
    • Annual Energy Outlook (AEO)
    • State Energy Data System (SEDS)
  • Federal Energy Regulatory Commission (FERC) Electric Utility Annual Report (Form 1)
  • National Household Travel Survey (NHTS) from the U.S. Department of Transportation Federal Highway Administration
  • American Community Survey (ACS) from the U.S. Census Bureau
  • Mineral Commodity Summaries from the U.S. Geological Survey (USGS)
  • National Emissions Inventory (NEI) and Greenhouse Gas Reporting Program (GHGRP) from the U.S. Environmental Protection Agency (EPA)
  • Gridded weather data from the National Aeronautics and Space Administration (NASA)
  • Technology cost and performance data from the Electric Power Research Institute (EPRI)
  • A variety of other sources providing detail on economic growth, policy, and biomass, among others

Further details on data sources are provided in the Resource and Technology Assumptions section. Note that this documentation is not intended to convey results and analysis arising from use of US-REGEN, although some limited results are shown to demonstrate how the model works. To access US-REGEN results, please see Reports and Publications.

Limitations and Assumptions of Energy-Economic Models

EPRI's US-REGEN model and other energy-economic models are necessarily numerical abstractions of the complex economic and energy systems they represent. US-REGEN is designed to show how changes in technology or policy constraints impact economic and energy-system activities relative to a baseline case; the optimization method and assumptions have been chosen and calibrated carefully to best align with this use. Doing so inevitably makes strong assumptions about the function of markets and energy electricity systems. The use of inter-temporal optimization implicitly assumes that actors will behave rationally in a competitive market with perfect information about current and future market conditions, including prices. For example, the model "knows" future gas prices and where and when the wind blows. The model is deterministic; that is, it does not include uncertainty, so that a given set of inputs and assumptions will produce the same outputs. This has the advantage of demonstrating the least-cost deployment mix of generation subject to a scenario-dependent range of technological and policy constraints and specified input assumptions. Apart from the impacts of uncertainty and imperfect information, economic theory suggests that it is reasonable to expect a least-cost outcome from a competitive market, which in some respects the wholesale generation of electric power has become.

These types of limitations and assumptions are common to the field of energy-economic modeling. Other prominent energy-economic models used in similar scenario analyses include the US-REP model developed by the Massachusetts Institute of Technology[2], the ADAGE model used by the Environmental Protection Agency (EPA)[3] and developed by RTI International, and the NEMS model developed by the Energy Information Administration (EIA)[4]. Prominent models similar to the US-REGEN electric sector model include the ReEDS model developed the National Renewable Energy Laboratory (NREL)[5], and the IPM model developed by the U.S. EPA and ICF[6].

Major Variations of US-REGEN

The US-REGEN model can be run in various configurations to examine a variety of research questions. The electric sector module has three modes: a dynamic long-run formulation that integrates fuels supply and can be optionally coupled with US-REGEN's end-use module or run standalone, a static hourly formulation that runs for a single year, and a unit commitment formulation that disaggregates the capacity blocks into individual units with ramp rates, start-up/shut-down costs, and other operational details. The latter two models can be "seeded" from dynamic model outputs. Below is a table of the characteristics of each version of US-REGEN, detailing the fundamental differences.

These characteristics are explored in more detail throughout the documentation. The Electric-Fuels Supply Model section describes the functionality of the dynamic electric sector model, its integration with fuel transformation sectors, and the static and unit commitment modes for the electric sector. The End-Use Model section describes the structure and functionality of the end-use model and how it interacts with the electric-fuels supply model.

Table 1: Characteristics of US-REGEN Model Variants
Dynamic (Electric Only)Static Equilibrium (Electric Only)Unit Commitment (Electric Only)Dynamic (Integrated Electric/Fuels/End-Use)
Optimization HorizonMulti-decadal (35 years)AnnualAnnualMulti-decadal (35 years)
Temporal Granularity~100 segments per year8,760 hours8,760 hours~100 segments per year
Capacity MixEndogenousUser PreferenceExogenous (from dynamic model run)Endogenous
Existing Unit Aggregation100+ capacity blocks per region (dispatched together)100+ capacity blocks per region (dispatched together)Individual units100+ capacity blocks per region (dispatched together)
StorageN/AEndogenousExogenousN/A
Geographical DetailUser-specified regions, up to state basedAll user-specified regionsAll user-specified regionsUser-specified regions, less than 20
Dispatch ConstraintsLoad balancingLoad balancingBalancing, min. load limits, ramp rates, start costs, etc.Load balancing
Optimization TypeLinear programLinear programMixed-integer programLinear program
SectorsElectric SectorElectric sectorElectric sectorEntire economy
Energy DemandExogenous, may use supply curves for some inputsExogenousExogenousEndogenous; detailed end-use model
Fuel PricesExogenous, may use supply curves for some inputsExogenousExogenousEndogenous; detailed fuels model

Reports and Publications

Please visit EPRI's Energy Systems and Climate Analysis public website (https://esca.epri.com/models.htmlopen in new window) for a list of freely-available EPRI reports and peer-reviewed publications that include US-REGEN modeling results.

A high-level slide deck introduction to US-REGEN can be found at: https://www.epri.com/research/products/000000003002032671open in new window.[7]

For a list of all EPRI publications that have been tagged with US-REGEN, please visit https://www.epri.com/search?productkeywords=US-REGENopen in new window.


  1. In defining the regions of the integrated model, there is necessarily a tradeoff between optimally representing the economy, where data is typically available along state lines, and optimally representing the U.S. electricity sector, the internal boundaries of which frequently cross state boundaries. ↩︎

  2. https://globalchange.mit.edu/sites/default/files/MITJPSPGC_Rpt194.pdfopen in new window ↩︎

  3. https://cfpub.epa.gov/si/si_public_record_report.cfm?Lab=OAP&dirEntryId=198000open in new window ↩︎

  4. https://www.eia.gov/outlooks/aeo/nems/documentation/open in new window ↩︎

  5. https://www.nrel.gov/analysis/reeds/open in new window ↩︎

  6. https://www.epa.gov/power-sector-modelingopen in new window ↩︎

  7. Young, et al. (2025). Introduction to EPRI's Regional Economy, Greenhouse Gas, and Energy (REGEN) Model. EPRI Report 3002032671. ↩︎

Last updated: May 23, 2025